Customer Updates: Stryker Network Disruption > Read Now
Treat PE differently.
Purpose-driven innovation. Proven clinical performance.
Designed for the single-session, lytic-free treatment of pulmonary embolism (PE).
The FlowTriever system offers patients suffering from acute PE immediate symptom relief and reversal of right heart strain that can lead to mortality and long-term morbidity.1
FLAME Study
The largest prospective study of interventional treatment in high-risk pulmonary embolism (PE).
FLASH Registry
The largest prospective interventional registry of pulmonary embolism (PE).
PEERLESS Study
The first randomized controlled trial (RCT) evaluating FlowTriever in the treatment of pulmonary embolism (PE).
PEERLESS II Study
Randomized controlled trial (RCT) of FlowTriever vs. anticoagulation alone in acute pulmonary embolism (PE).
Connect with an expert
Engage with us on social media to find information about upcoming MedEd events, including webinars, and to be among the first to receive news on technology enhancements, new clinical data and more.
Indications For Use
The FlowTriever Retrieval/Aspiration System is indicated for (1) The non-surgical removal of emboli and thrombi from blood vessels. (2) Injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel. The FlowTriever Retrieval/Aspiration System is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism. The Triever Catheters are indicated for (1) The non-surgical removal of emboli and thrombi from blood vessels. (2) Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel. The Triever Catheters are intended for use in the peripheral vasculature and for the treatment of pulmonary embolism. The Triever Catheters are also intended for use in treating clot in transit in the right atrium, but not in conjunction with the FlowTriever Catheters. The FlowTriever2 Catheter is indicated for (1) The non-surgical removal of emboli and thrombi from peripheral blood vessels. (2) Injection, infusion and/or aspiration of contrast media and other fluids into or from a blood vessel. The FlowTriever2 Catheter is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism (PE). The Triever20 Curve Catheter is used coaxially within the Triever24 Catheter for (1) The non-surgical removal of emboli and thrombi from blood vessels. (2) Injection, infusion, and/ or aspiration of contrast media and other fluids into or from a blood vessel. The Triever20 Curve Catheter is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism. The Triever20 Curve Catheter is not indicated for use with the FlowTriever Catheters. The Triever20 Curve Catheter is also intended for use in treating clot in transit in the right atrium, but not in conjunction with the FlowTriever Catheters. The Triever20 Curve Catheter must be used within the Triever24 Catheter. The Triever16 Curve Catheter is indicated for (1) The non-surgical removal of emboli and thrombi from blood vessels. (2) Injection, infusion, and/or aspiration of contrast media and other fluids into or from a blood vessel. The Triever16 Curve Catheter is intended for use in the peripheral vasculature and for the treatment of pulmonary embolism. The Triever16 Curve Catheter is not indicated for use with the FlowTriever Catheters. The Triever16 Curve Catheter is also intended for use in treating clot in transit in the right atrium but not in conjunction with the FlowTriever Catheters. The FlowSaver Blood Return System is used with Inari Medical catheters and sheaths for autologous blood transfusion.
Review complete Instructions for Use, Indications for Use, Warnings, Precautions, Possible Adverse Effects and Contraindications prior to use of the product.
Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.
PRO-3800-USA-EN-v1