Related categories

Trevo NXT ProVue Retriever
The original stent retriever brand purpose-built for stroke.

Over the last decade, few devices in neurovascular care have been studied as extensively— or trusted as widely—as the Trevo Retriever. Backed by a global body of evidence spanning nearly 9,000 patients across registries and observational studies, Trevo has not only shaped stent retriever thrombectomy—it continues to evolve, driven by the insight, innovation, and feedback of the clinicians who use it.

Trevo NXT product image

Features and benefits

Proven efficacy

Trevo retrievers are designed to maximize clot integration and provide meaningful procedure guidance with full-length radiopacity.

SNV-4869-Trevo-NXT-6x37-RT-2-R1

Trevo Retriever

Actionable real-time insights
with full-length radiopacity.

push-deployment-graphic

Active push deployment

The laser cut tube and vertical struts are designed for clot integration and improved revascularization.4

A) Before retrieval
B) During retrieval

stent-struts-graphic

Designed to lock on and secure clot
with large cells and high on-clot radial force to integrate different clot types.

A) Trevo stent struts
B) Conventional stent struts

Compatibility without trade-offs

With the Trevo NXT ProVue Retriever, you can now deliver the full range of Trevo NXT ProVue Retriever sizes through the Trevo Trak 21 Microcatheter without compromising on the stent design you trust.

triglide-wire-graphic

TriGlide delivery wire technology

Distal polymer jacket and hydrophilic coating for smooth delivery.

The evolution of Trevo Retrievers:
timeline-graphic

Clinical evidence

Driven by the evidence, insights and feedback of the clinicians who use it.
evidence-timeline-graphic

Learn more about Stryker's clinical evidence

*206 patients were enrolled; 107 patients were assigned to the Trevo group. **1,492 patients were enrolled; 944 patients had Trevo as their first device. †2012 patients enrolled; 1541 patients had Trevo as their first device. ‡1,885 were eligible for inclusion; 245 patients had Trevo as their first device.

* Studies conducted using Trevo XP which has been shown to be substantially equivalent to Trevo NXT.

Specifications and compatibility

Specifications

Stent diameter Labeled length Stent length Device length Wire diameter
3 32 mm 36 mm 200 cm 0.015 in
4 28 mm 32 mm 200 cm 0.019 in
4 41 mm 44 mm 200 cm 0.019 in
6 37 mm 40 mm 200 cm 0.019 in

Compatibility

Trevo NXT ProVue Retriever Compatible microcatheter
3x32 Trevo Trak 21 Microcatheter
4x28 Trevo Trak 21 Microcatheter
4x41 Trevo Trak 21 Microcatheter
6x37 Trevo Trak 21 Microcatheter

Techniques and portfolio

Trap technique

A)    Trevo NXT
                ProVue Retriever

          Trevo Trak 21
                Microcatheter

B)    AXS Catalyst 6
               Distal Access Catheter

C)    FlowGate2
               Balloon Guide Catheter

D)    AXS Universal
               Aspiration System

Trevo combination technique

A)    AXS Universal
    
     Aspiration System

B)    AXS Infinity LS Plus
               Long Sheath

C)    AXS Vecta 71
              Intermediate Catheter

D)    Trevo NXT
               ProVue Retriever

       Trevo Trak 21
                Microcatheter

Trevo animation video

Contact us

Thank you!