Broadway 
System*

Individually strong.
Together, unstoppable.

 

Four purpose-built devices. One integrated super-bore aspiration platform. The Broadway System is designed to support the full path from initial access to aspiration at the clot face.

Broadway_Full_System_003-v1

Power only matters if it reaches the clot face.

Our approach to innovation begins with understanding where meaningful progress is still needed. In aspiration, the mission is clear: reach the clot face and restore blood flow as quickly as possible. But the path is rarely simple. 

For years, a fundamental tradeoff has persisted between aspiration power and the trackability and support needed to navigate complex anatomy and reach the clot face.

That's where we focused.


Four devices.
Designed for the full path.

The Broadway System* brings together four devices as one coordinated aspiration solution, with each component serving a distinct purpose across access, support, delivery and aspiration. Each part has a role. Each detail has a reason.

Dash Hydrophilic Short Sheath-dimensional-frame.jpg

Dash Hydrophilic Sheath Introducer

Establish initial access 

A thin-wall, braided-reinforced hydrophilic short sheath designed to accommodate the 9F Broadway System* while maintaining a familiar 8F closure approach.

Echo Intracranial Base Catheter-dimensional frame

Echo Intracranial Base Catheter

Build proximal support

A supportive intracranial base catheter with a 2.54 mm / 0.100 in inner diameter, designed to provide the stability and lumen needed to deliver Broadway 8.

Create the pathway-dimensional frame

FastPass Delivery Assist Catheter

Create the pathway 

A delivery assist catheter designed to minimize the ledge and support smooth navigation of Broadway 8 into the M1.

Broadway 8 Catheter-dimensional frame

Broadway 8 Catheter

Bring aspiration to the clot

A super-bore aspiration catheter with a 2.13 mm / 0.084 in inner diameter and a 2.41 mm / 0.095 in distal outer diameter, designed to balance aspiration performance with the navigability needed to reach the M1.

 

  

Designed to reach the clot.

36OMax™ Laser Technology is the engineering approach behind Broadway and Echo’s balance of lumen size, flexibility, support and trackability.


Our patented technology leverages thousands of laser cuts in a stainless steel hypotube to create distinct structural patterns that balance flexibility and support while maintaining lumen patency and kink resistance.


01

Flexibility

Supports navigation through complex anatomy.

02

Support

Helps create a stable path toward the target.

03

Lumen patency

Designed to preserve the working lumen.

04

Kink resistance

Supports responsive catheter performance.

 

  

A: Echo proximal "supportive" cut pattern

B: Broadway 8 distal "flex" cut pattern

360MAX-labeled

Vessel-matched clot aspiration.
Sized with intention.

Once delivered to the target vessel, Broadway 8 is designed to support clot engagement and efficient aspiration, helping physicians remove clot and restore blood flow.


Its 2.41 mm / 0.095 in distal outer diameter and 2.13 mm / 0.084 in inner diameter were purposefully selected based on research across hundreds of patients. In the ASSIST Registry, the average M1 diameter was 2.43 mm.

  

2.43 mm

Average M1 diameter
ASSIST Registry

2.41 mm

Broadway 8 distal OD
Purposefully matched to M1 anatomy

2.13 mm / 0.084 in

Broadway 8 inner diameter
Super-bore aspiration lumen

  


The evidence

Designed with intention. Refined with evidence.


The Broadway System* was built to help physicians bring super-bore aspiration to the clot face without sacrificing the navigation needed to get there. Early pre-clinical testing and physician experience supports that design intent.

M1 access success 

Pre-clinical testing, N=381

Final TICI 2b+

Early clinical experience with the Broadway System2

“It’s amazing that something this big can get in the M1 – really smooth.”

Dr Manuel Moreu – Neurointerventional Radiology
Hospital Clínico San Carlos, Madrid, Spain


Peer-reviewed publications

"Initial multicenter experience with the Broadway System for direct aspiration of large vessel occlusions in acute ischemic stroke"

Argyle V. Bumanglag, et al.
Sage Journals

  

"Broadway 8 system: a multicenter early evaluation of safety, performance, and clinical outcomes in mechanical thrombectomy"

Rime Ezzeldin, et al.
BMJ Journals

  

"Echo intracranial base catheter use in neuroendovascular procedures: Institutional experience"

Maher Hosain, et al.
Sage Journals

  


Specifications

Inner Diameter

3.20 mm / 0.126 in

Length

11 cm

Inner Diameter

2.54 mm / 0.100 in

Outer Diameter

3.00 mm / 0.118 in

Length

100 cm and 105 cm

Inner Diameter

0.41 mm / 0.016 in

Distal Outer Diameter

0.84 mm / 0.033 in

Bulb Outer Diameter

1.91 mm / 0.075 in

Length

156 cm

Inner Diameter

2.13 mm / 0.084 in

Proximal Outer Diameter

2.49 mm / 0.098 in

Distal Outer Diameter

2.41 mm / 0.095 in

Length

132 cm