Triathlon® Cementless

Fixation you can trust.

Triathlon Cementless combines the kinematics of Triathlon with the latest highly porous biologic fixation technology. With over one and a half million cementless knees implanted to date1 and impressive survivorship data2-4 since it was introduced in 2013, Triathlon Cementless has become a trusted solution5-7 for surgeons across the globe.

Recent published clinical studies with mid‑ to long‑term follow‑up demonstrate excellent survivorship of cementless Triathlon titanium tibial baseplates, with reported overall survivorship of approximately 96–99% at 5 to 10 years and very low rates of aseptic loosening.2-4 In 10‑year follow‑up studies of cementless, highly porous and three‑dimensionally printed titanium tibial baseplates, aseptic loosening survivorship exceeded 98%, with no evidence of progressive loosening after early postoperative fixation.3,4 The American Joint Replacement Registry (AJRR) across 428 institutions and over 28,000 Triathlon Cementless baseplate showed 99% survivorship at four years.2

Image of Stryker's Triathlon Cementless knee
X

Triathlon® Cementless – Fixation you can trust. | Stryker

 

 

Side view image of Triathlon Cementless

Triathlon Cementless

Fixation you can trust.

Trusted results.3-4

Improved efficiency.8-10

High satisfaction.9-11

Design

Triathlon design

Stable primary fixation of the implant is necessary for biologic fixation.12 The less constrained the design, the less potential there is for stresses generated at the articulating surface to be transferred to the bone-implant interface.13 Triathlon is designed to minimize dynamic stress transfer to the tibial fixation interface by providing minimal resistance to internal and external motion and by locating the bearing sulcus directly over the tibial keel to help reduce sagittal rocking during ambulation.14

images of Triathlon design

Triathlon Cementless Patella

The architecture on the back side of the Triathlon Cementless Patella, combined with a direct compression molding process, is designed to minimize the potential for dissociation.15 Additive manufacturing makes it possible to build a solid barrier layer between the porous surfaces, which allows for a smaller metal backing and greater polyethylene thickness.

JR-Knee-Triathlon-Cementless-Hero-image02

Initial stability

Given the importance of stable primary fixation,12 the underside of the Triathlon Cementless Baseplate was designed to reduce micromotion and liftoff.16 Additive manufacturing technology provided our engineers the ability to think of a design, 3D print it and then test it.


SOMA designed

Stryker Orthopaedics Modeling and Analytics (SOMA) is a global database of bone morphology – size, shape, density, stiffness and inner and outer cortical diameters – drawn from diverse populations. SOMA was used to optimize the depth and placement of the Tritanium pegs.17 The Triathlon Cementless Baseplate’s size-specific peg design allows for purchase into denser regions of bone without perforating the cortex.17

SOMA designed images - sizes 1, 4 and 8

Additive manufacturing technology

Components for the Triathlon Cementless Baseplate and Patella are additively manufactured using a focused laser beam to sinter numerous layers of titanium powder, which grows the implant structure layer by layer.

With additive manufacturing technology, we can strategically position porous structures in the desired zones of the Triathlon Tritanium Baseplate. Avoiding porous metal in the distal areas may help reduce risks of stress shielding.

detail image of cancellous bone and Tritanium porous matrix

Efficiencies

Potential savings in time and cost

As the volume of TKA procedures continues to increase, the costs associated with this surgical procedure continue to be an important topic. 

Triathlon Cementless allows the potential to reduce operating room time8-9 and save expenses without the use of bone cement and cement accessories.10

Two healthcare economic studies in the U.S. concluded that the actual overall cost of cementless TKA could be offset by shortened operating room time and the lack of need for cement and cementing accessories.10,18*

Several studies have shown using Triathlon Cementless can save 10-15 minutes of OR time8-9 by eliminating the need to mix and apply bone cement.

*Cost savings may differ across regions due to different healthcare systems, treatment plans and associated costs. 

Side view image of Triathlon Cementless

Clinical outcomes

Triathlon Cementless TKA demonstrated excellent clinical outcomes in multiple studies with ten-year follow-up3,4 and achieved similar functional outcomes as well as pain reduction compared to cemented Triathlon TKA in multiple short- to midterm studies.17-19

The mid-term performance of the Triathlon Cementless baseplate was investigated using data from the American Joint Replacement Registry (AJRR).Triathlon Cementless baseplate cases (N=28,631) from 428 institutions were identified. These cases were compared to all other “Aggregated Cementless” as well as “Aggregated Cemented” knee cases. Implant survivorship free of revision was 98.9% (CI 98.7-99.0), with the Triathlon Tritanium baseplate, 98.3% (CI 97.9-98.6), in the aggregate cementless group and 98.4% (CI 98.4-98.5) in the cemented knee group at 60-month follow-up (p<0.001).2

JR-Knee-Triathlon-Cementless-Hero-image02
99%
Trusted results
Survivorship at ten years3-4
image indicating shorter operating time
Improved efficiency
Shorter OR time in cementless TKA8-9
Higher satisfaction icon with a thumb and happy face
High satisfaction
Enhanced early9 and midterm11 patient satisfaction
icon of a person walking upstairs
May provide earlier return to function9
illustration of knee pain
Similar pain reduction19

Mako compatibility

Mako SmartRobotics™ combines 3D CT-based planning and Accustop™ haptic technology into one platform that has shown better outcomes compared to manual surgery for your total knee, total hip and partial knee patients.20-22

Unlock the powerful combination of Mako SmartRobotics™ and Triathlon Cementless. 

Mako’s 3D CT-based planning allows you to see more of your patient’s unique anatomy and accurately plan Triathlon in the coronal, transverse and sagittal planes for each patient.21

To learn more about Mako SmartRobotics™ click here.

Did you know? Triathlon Cementless implants make up over half of the Mako Total Knees implanted in the U.S.1

Mako Total Knee system