It seems like you are using an older browser, please update your browser for a better user experience.

Stryker Target® Detachable Coils

Inzone Detachment SystemBipolar Pathway

Target® Detachable Coils with Tenzing™ Technology

Target® Detachable Coils with Tenzing™ Technology are manufactured by Boston Scientific for Stryker Neurovascular.

Advance with Confidence.

The Formula for Exceptional Performance
Introducing a revolutionary formula for product development. With Tenzing Technology, quality, process, and design come together to create a platform where no single feature stands alone. Each element of the Target Detachable Coil system has been optimized to work together, resulting in exceptional coil performance.

Experience Tenzing Technology.

90645804.AB



Features & Benefits

Balanced Design
Engineered to optimize both pushability and flexibility, resulting in a new level of tactile sensation.

Controlled Delivery
Experience the difference throughout the entire delivery process – from enhanced trackability through the microcatheter, to smoother coil positioning, and improved stability upon marker alignment.

Target®  360 Ultra Coil
Our softest complex coil ever, the Target 360 Ultra Detachable Coil unites finishing-coil softness with the Gold Standard in shape. Experience the benefits of 360 from Start to Finish.

Ready. Set. Detached.
Fast detachments† and real-time feedback are just a click away with an advanced interface that keeps you up to speed.



1. COMPREHENSIVE OFFERING
Target Coil family provides an expanded suite of 10-size 360 and helical coils, including longer lengths and the first bare complex finishing coil in the Target 360 Ultra Detachable Coil

2. FLEXIBLE JUNCTION
Softer, shorter junction engineered to minimize kickback for increased control and stability

3. LASER-ABLATED DETACHMENT ZONE
New design uses 82% less metal for fast detachments with no compromise to tensile strength

4. DARKER RADIOPAQUE MARKER
Enhances visibility to facilitate accurate alignment

5. BIPOLAR PATHWAY
Centralized electrodes allow for quicker system setup by eliminating the need for a grounding cable and needle

6. HYBRID DELIVERY WIRE
Balanced stiffness zones provide an optimized combination of flexibility and pushability to yield a one-to-one feel

7. FLUORO-SAVER MARKER
Intended to reduce radiation exposure time for physicians and patients

8. INZONE DETACHMENT SYSTEM
Streamlines detachment process with increased speed, direct feedback, and greater control


† Average < 5 seconds based on bench test data (n=22).

Bench test results may not necessarily be indicative of clinical performance. Testing completed by Boston Scientific Corporation. Data on file and available upon request.

* Bench testing data (n=22).

All photographs taken by and on file at Boston Scientific Corporation.